Types of Air System Tests. AMCA International's lab performs tests on the following products: Fans. Air performance testing includes: Development of fan curves. Measurement of airflow, pressure, power, and efficiency. Test standards that apply to air performance testing include: AMCA International's 2. Laboratory Methods of Testing Fans for Aerodynamic Performance Rating. AMCA International's 2. Test Methods for Air Curtain Units. AMCA International's 2. Laboratory Methods of Testing Air Circulator Fans for Rating. AMCA International's 2. Laboratory Method of Testing Positive Pressure Ventilators for Rating. ISO 5. 80. 1, Industrial Fans - Performance Testing Using Standardized Airways. ENERGY STAR Program Requirements for Residential Ventilating Fans. Sound testing includes: Inlet sound power. Outlet sound power. Total sound power. Test standards that apply to sound testing include: AMCA International's 3. Reverberant Room Method for Sound Testing of Fans. ENERGY STAR Program Requirements for Residential Ventilating Fans. Dampers. Pressure drop. Leakage performance. Test standards that apply to damper testing include: AMCA International's 5. D, Laboratory Methods of Testing Dampers for Rating. Louvers. Pressure drop. Leakage. Resistance to water and wind driven rain. Transmission loss of acoustic louvers. Sound testing is per ASTM E- 9. Test standards that apply to louver testing include: AMCA International's 5. L, Laboratory Methods of Testing Air Louvers for Rating. Airflow Measurement Stations. Accuracy and pressure drop. Test standards that apply to airflow measurement station testing include: AMCA International's 6. This International Standard deals with the determination of the performance of industrial fans of all types except those designed solely for air circulation e.g. Methods of Testing Airflow Measurement Stations for Rating. Test standards that apply to fire, smoke, combination fire/smoke dampers testing include: AMCA International's 5. D, Laboratory Methods of Testing Dampers for Rating. Underwriters Laboratories 5. Fire Dampers. Underwriters Laboratories 5. S, Smoke Dampers. Contract Testing. Non- standard tests can be performed to meet customer requirements when within the physical capabilities of AMCA International's facilities. Facilities: Reverberant Sound Rooms (Four)Range in size from 6,3.
DIN EN ISO 5801 (2010-12) Industrial fans - Performance testing using standardized airways (ISO 5801:2007, including Cor 1:2008). Standard meta description. Industrial fans - Performance testing using standardized airways - ISO 5801:2007.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. Archives
November 2017
Categories |